Sending the Calibrations to Multiple ECM (Cummins QSKTA50-CE/ QSK60 Engine)

QSKTA50-CE / QSK60

Figure 1.1 - Cummins QSK60

Check for the latest ECM Code 
1). Connect to the ECM with INSITE™, and click the Calibration Selection on the Viewbar to select, view, and transfer calibration.
2). Click the ECM/PDD Code Search (Web/Online). Once complete, click the Save button.
Figure 1.2 - ECM/PDD Code Search

Download the calibrations to ECM
1). Click the ECM/PDD, navigate to the desired calibration and click to highlight it.
2). Double-click the highlighted calibration (ECM Code: AQ60365.20) or right-click on the calibration and select Transfer to ECM
Figure 1.3 - Transfer to ECM
3). Read the "Warning!" message displayed on the welcome page carefully and select Next to continue.
Figure 1.4 - Warning! message (Next)

Multiple ECM Download (3 ECMs)
4). Choose = Calibrate Engine Control System (Single Key-Off)
→To calibrate the entire system or more than a single ECM.
Figure 1.5 - Choose Multiple Module
5). Select Next to proceed to the Adjustable Parameter Recovery File window. 
6). A System ID and Dataplate Information window will open.
Verify or modify the System ID and Dataplate information (Primary ECM = AQ60365.20). The values that are not locked may be changed by double-clicking in the right-hand column and entering a new value. Click Next.
Figure 1.6 - Primary ECM (0/Undefined)
Select Calibration
→Select an ECM Code to be downloaded (Secondary ECM 1 = AR60325.15). Click Next.
Figure 1.7 - Select Calibration (AR60325.15)
Verify or modify the System ID and Dataplate information (Secondary ECM 1 = AR60325.12). The values that are not locked may be changed by double-clicking in the right-hand column and entering a new value. Click Next.
Figure 1.8 - Secondary ECM 1 (1/Secondary 1)
→Select an ECM Code to be downloaded (Secondary ECM 2 = AR60326.13)Click Next.
Figure 1.9 - Select Calibration (AR60326.13)
Verify or modify the System ID and Dataplate information (Secondary ECM 2 = AR60326.11). The values that are not locked may be changed by double-clicking in the right-hand column and entering a new value.
If desired, select Save/Restore Adjustable Parameters if available. This option saves the adjustable parameters and then restores them to the ECM after calibration download has been successfully completed. If Save/Restore Adjustable Parameters is not selected, or if the connected ECM does not support it, the adjustable parameters will be set to the default values of the new calibration. NOTE: The Save/Restore Adjustable Parameters option is unchecked by default for industrial applications and checked for automotive applications.
To undo changes, click Restore Original Values or select Next to continue.
7). Verify the Summary information is correct and select Next to continue.
Figure 2.1 - Summary
8). An Adjustment Confirmation message will appear. Select OK to continue.
Figure 2.2 - Adjustment Confirmation
9). INSITE™ will begin calibrating the ECM. Follow the prompts and do not turn off the key switch unless instructed.
Figure 2.3 - Calibration Transfer (Primary ECM)
→Please continue when the transfer is complete.
Figure 2.4 - Calibration Transfer (Secondary 1)
10). At the end of the calibration download, it will be necessary to cycle the key switch. Follow the INSITE™ prompts as required. 
Figure 2.5 - Key Switch (Off)
→Waiting 30 seconds before allowing for Key On.
Figure 2.6 - Waiting for Key On
→Please turn the Key Switch On, and then click OK.
Figure 2.7 - Turn Key Switch On
→Calibration Transfer Results = Successful.
Figure 2.8 - Calibration Transfer Results
11). After calibration transfer has completed, the results of the calibration transfer and Save and Restore (if selected) will be displayed in the Calibration Transfer Results window. This will also appear in the summary of the Calibration Transfer window. Select OK
If some of the parameters can't be restored, they will be listed in the Parameters Not Restored window. This list of parameters can be saved or printed, and can be manually adjusted through Features and Parameters on the View bar.
12). Select Next to continue.
Figure 2.9 - Calibration Transfer Summary
13). Select Finish to close the ECM Calibration Download Wizard.
Figure 3.1 - Finish
→Work Order/Image Creation (New ECM Image).