Sending the Calibrations to Multiple ECM (Cummins QSKTA50-CE/ QSK60 Engine)
QSKTA50-CE / QSK60
![]() |
| Figure 1.1 - Cummins QSK60 |
Check for the latest ECM Code
1). Connect to the ECM with INSITE™, and click the Calibration Selection on the Viewbar to select, view, and transfer calibration.
2). Click the ECM/PDD Code Search (Web/Online). Once complete, click the Save button.
![]() |
| Figure 1.2 - ECM/PDD Code Search |
Download the calibrations to ECM
1). Click the ECM/PDD, navigate to the desired calibration and click to highlight it.
2). Double-click the highlighted calibration (ECM Code: AQ60365.20) or right-click on the calibration and
select Transfer to ECM.
![]() |
| Figure 1.3 - Transfer to ECM |
Multiple ECM Download (3 ECMs)
4). Choose = Calibrate Engine Control System (Single Key-Off)
→To calibrate the entire system or more than a single ECM.
5). Select Next to proceed to the Adjustable Parameter Recovery File
window.
6). A System ID and Dataplate Information window will open.
→Verify or modify the System ID and Dataplate information (Primary ECM = AQ60365.20). The
values that are not locked may be changed by double-clicking in the right-hand
column and entering a new value. Click Next.
![]() |
| Figure 1.6 - Primary ECM (0/Undefined) |
Select Calibration
→Select an ECM Code to be downloaded (Secondary ECM 1 = AR60325.15). Click Next.
![]() |
| Figure 1.7 - Select Calibration (AR60325.15) |
![]() |
| Figure 1.8 - Secondary ECM 1 (1/Secondary 1) |
→Select an ECM Code to be downloaded (Secondary ECM 2 = AR60326.13). Click Next.
![]() |
| Figure 1.9 - Select Calibration (AR60326.13) |
→If desired, select Save/Restore Adjustable Parameters if
available. This option saves the adjustable parameters and then restores them to
the ECM after calibration download has been successfully completed. If Save/Restore Adjustable Parameters is not selected, or if the connected ECM does not
support it, the adjustable parameters will be set to the default values of the
new calibration. NOTE: The Save/Restore Adjustable
Parameters option is unchecked by default for industrial applications and
checked for automotive applications.
→To undo changes, click Restore Original Values or select
Next to continue.
7). Verify the Summary information is correct and select Next
to continue.
![]() |
| Figure 2.1 - Summary |
![]() |
| Figure 2.2 - Adjustment Confirmation |
![]() |
| Figure 2.3 - Calibration Transfer (Primary ECM) |
![]() |
| Figure 2.4 - Calibration Transfer (Secondary 1) |
![]() |
| Figure 2.5 - Key Switch (Off) |
![]() |
| Figure 2.6 - Waiting for Key On |
→Please turn the Key Switch On, and then click OK.
![]() |
| Figure 2.7 - Turn Key Switch On |
→Calibration Transfer Results = Successful.
![]() |
| Figure 2.8 - Calibration Transfer Results |
11). After calibration transfer has completed, the results of the calibration
transfer and Save and Restore (if selected) will be displayed in the
Calibration Transfer Results window. This will also appear in the summary of the
Calibration Transfer window. Select OK.
→If some of the parameters can't be restored, they will be
listed in the Parameters Not Restored window. This list of parameters can be
saved or printed, and can be manually adjusted through Features and Parameters
on the View bar.
12). Select Next to continue.
![]() |
| Figure 2.9 - Calibration Transfer Summary |
![]() |
| Figure 3.1 - Finish |