FREE Cummins INSITE Software: Cruise Control - PTO/Remote PTO (ISC/Transit Bus ISL8.3)

PTO Status (Normal PTO Active/ Inactive)

Figure 1.1 - PTO Telltale (Dash Panel)

1). Access the Features and Parameters for PTO/Remote PTO settings. Read More: Power Take-Off (PTO) Operation on CUMMINS Engines.
Figure 1.2 - PTO/Remote PTO (Adjustable Parameters)
→Maximum PTO Speed = 1314 RPM
→Minimum PTO Speed = 700 RPM
→PTO Ramp Rate = 100 rpm/s
→PTO Resume Switch Speed = 700 RPM
→PTO Set Switch Speed = 1314 RPM

2). Use the Data Monitor/Logger to view parameters for monitoring the PTO/Remote PTO settings. Read More: Data Monitor/Logger on Cummins INSITE Software (CUMMINS Engines).
Figure 1.3 - Data Monitor/Logger (Custom)
Starts the Engine, and wait until the Air Supply is provided before the PTO operation. Shift Transmission to Neutral, and set Parking Brake.
#Monitoring parameters related to PTO/Remote PTO:
→Cruise Control ON/OFF Switch = Off
→PTO ON/OFF Switch = Off
→PTO Reference Speed = 700 RPM (PTO Resume Switch Speed)
→PTO Set/Resume Switch = Neutral
→PTO Status = Inactive

3). Activate the PTO operation.
Figure 1.4 - PTO ON/OFF Switch (On)
Depress Clutch (Clutch Pedal Position Switch = Depressed), shift PTO Control Valve to ON position, and release Clutch. Then set Cruise Control Switch to ON position (also will activate PTO ON/OFF Switch), and bump Set/Resume Switch to SET position.
→Cruise Control ON/OFF Switch = On
→PTO ON/OFF Switch = On
→PTO Reference Speed = 700 RPM (PTO Resume Switch Speed)
→PTO Set/Resume Switch = Set/Increment
→PTO Status = Inactive
Engine will automatically ramp up to Pre-set RPM's (refer to Figure 1.2 above).
Figure 1.5 - PTO Status (Normal PTO Active)
→Cruise Control ON/OFF Switch = On
→PTO ON/OFF Switch = On
→PTO Reference Speed = 1314 RPM (PTO Set Switch Speed)
→PTO Set/Resume Switch = Neutral
→PTO Status = Normal PTO Active
Figure 1.6 - Cruise Control/Set/Resume Switch, PTO Control Valve

*Additional Information:
→Cruise Control/ PTO Set/Resume Switch - OEM Connector (Pin 24, 25)
→Cruise Control/ PTO Switch - OEM Connector (Pin 16)
→Accelerator Interlock Switch - OEM Connector (Pin 13)
→Clutch Pedal Position - OEM Connector (Pin 15)
→Accelerator Pedal Assembly
Signal - OEM Connector (Pin 09)
Off Idle Signal - OEM Connector (Pin 01)
Idle Signal - OEM Connector (Pin 11)
 

Read More: