IFM Moneo Configure Device - Connecting to the Device (PV7601)

IFM Moneo - AL1060 I/O Link Master

Figure 1.1 - I/O Link Master (1 Port USB)

P/N 2330-ZZ1060-ND (MFG P/N ZZ1060)
I/O Link Master with USB Interface

Figure 1.2 - IFM Moneo (Login)

#Configure Device
Figure 1.3 - IFM Moneo (Local Host)

1). Scanning the network for device
→Network Settings - USB Port (I/O-Link Master E30390 and AL1060), search for IO-Link USB master E30390 or AL1060 connected directly via USB port. The Ethernet network will not be scanned.
→Device Type (I/O-Link Master).
Figure 1.4 - Network Scan
→Click on SCAN.
The network is scanned for available devices according to the selected search option. The progress bar shows the progress of the search.
Figure 1.5 - Network Scan (I/O-Link Master)
The table lists all detected devices.
The device ports and connected sensors / actuators appear (PV7601).
Figure 1.6 - I/O-Link Device (PV7601)
The user has access to additional device functions.
Figure 1.7 - Frac Pump Switch (PV7601)

2). Set the Parameters
→Click on WRITE CHANGES TO DEVICEThe parameter set is written to the device and activated.
Figure 1.8 - Write to Device
→Click on SAVE PARAMETER SET to save the parameter set.
Figure 1.9 - Save Parameter Set