Caterpillar ET Software: Test the Connection to the ECM using CAT Communication Adapter 3 Toolkit
Using the CA3 Toolkit
Figure 1.1 - CAT Comm Adapter 3 (3512B Well Service) |
Use CAT Communication Adapter 3 Toolkit to test the connection between the CAT Communication Adapter 3 and the ECM Caterpillar Engines.
#Download Driver for CAT Comm Adapter 3 here:
Preparing to use the CAT Communication Adapter 3 Toolkit
1). Prepare your PC, and connect CAT Comm Adapter 3 to Diagnostic Port/Connector to the ECM.
2). Click "Start" - "All Programs" - "Caterpillar Comm Adapter 3" - "Comm Adapter 3 Toolkit", or through shortcut "Comm Adapter 3 Toolkit" on desktop.
Figure 1.3 - CAT Comm Adapter 3 Toolkit - CA3 detected |
→Select Utilities - Communication Adapter 3 Toolkit.
Figure 1.4 - Communication Adapter 3 Toolkit (Utilities) |
Figure 1.5 - Communication Adapter 3 Toolkit (CA3 detected) |
3). Once CA3 was detected, close the CAT Communication Adapter 3 Toolkit and open the CAT ET Software.
4). The Connection message box is displayed while the service tool attempts to
establish communications with the data link.
5). To cancel all attempts to communicate with the ECM, click the "Stop Connect" button on the Connection message box. All functions that require an active data link connection are disabled. The service tool displays a blank main screen. The status bar is updated with the message "Disconnected."
Figure 1.6 - Attempting to detect an ECM |
5). To cancel all attempts to communicate with the ECM, click the "Stop Connect" button on the Connection message box. All functions that require an active data link connection are disabled. The service tool displays a blank main screen. The status bar is updated with the message "Disconnected."
Figure 1.7 - 1 ECM detected (Initializing...) |
6). When communications are successfully established and a single ECM is found,
the "ECM Summary" screen displays. When communications are successfully established and multiple ECMs are found,
the ECM Selector dialog box displays. If the service tool connects to an ECM
that is not supported by the subscription, the service tool displays a message
and immediately disconnects.
7). If any problems while trying to Initializing communications to the ECM, it will displays "Cat Electronic Technician" message to provides
information for correcting the problems as example below.
Figure 1.8 - ECM Summary |
Figure 1.9 - Communications Adapter Error |
Figure 2.1 - Troubleshooting Guide |
Read More:
Blog.Teknisi
Thanks for Sharing!
ReplyDeleteReally a nice post.
Now You Can Easily Download Every Crack Software From Here*
Please Visit!
MakeMusic Finale crack
Broadgun pdfMachine Ultimate crack
PowerISO crack
Driver Toolkit crack
KeyShot Pro Crack
I guess I am the only one who comes here to share my very own experience guess what? I am using my laptop for almost the post 2 years.
ReplyDeleteDriver Toolkit Crack
Modo Bass Crack
Lexicon Bundle Crack
EagleFiler Crack